Effect of recasting on physical properties of base metal alloys: An in vitro study


Jittin James1, Jose Julian2, J Rahul1, Gibi Babu Philip3, Jinsa P Devassy1, PB Reba4,  
1 Department of Prosthodontics, Mar Baselios Dental College, Ernakulam, Kerala, India
2 Department of Prosthodontics, Indira Gandhi Institute of Dental Science, Ernakulam, Kerala, India
3 Department of Prosthodontics, Azeezia College of Dental Science and Research, Kollam, Kerala, India
4 Department of Prosthodontics, St. Gregorios Dental College, Ernakulam, Kerala, India

Correspondence Address:
Dr. Jittin James
Department of Prosthodontics, Mar Baselios Dental College, Kothamangalam, Ernakulam, Kerala
India

Abstract

Aims and Objectives: This study aims to establish the outcome of recasting on tensile strength, modulus of elasticity, and hardness of Nickel–chromium alloys. Materials and Methods: Fifty wax patterns were fabricated, using the lost wax technique, the measurements of which were standardized. They were categorized into five groups of ten each. Group I included samples casted with new alloy alone. Group II samples consisted of 75% new alloy and 25% once casted alloy. Group III was casted with 50% of each. Group IV with 25% new metal and 75% previous alloy and samples of Group V samples were casted with once casted alloy alone. Modulus of elasticity and tensile strength were measured by universal testing machine, whereas hardness using microhardness tester. The values were statistically analysed. IBM Corp. Released 2011. IBM SPSS Statistics for Windows, Version 20.0. IBM Corp, Armonk, NY, USA. for Windows software was used for analysis. Results: We found a slight variation in mean tensile strength and modulus of elasticity, which was statistically insignificant variation among the groups. However, there was a significant difference in mean hardness between Groups III, IV, and V. Conclusion: It is prudent to use pure alloy alone for casting. However, in view of environment and economical factors, addition of <50% reused alloy to pure alloy is satisfactory clinically.



How to cite this article:
James J, Julian J, Rahul J, Philip GB, Devassy JP, Reba P B. Effect of recasting on physical properties of base metal alloys: An in vitro study.J Int Soc Prevent Communit Dent 2018;8:457-462


How to cite this URL:
James J, Julian J, Rahul J, Philip GB, Devassy JP, Reba P B. Effect of recasting on physical properties of base metal alloys: An in vitro study. J Int Soc Prevent Communit Dent [serial online] 2018 [cited 2023 Jan 30 ];8:457-462
Available from: https://www.jispcd.org/text.asp?2018/8/5/457/242870


Full Text

 Introduction



The procedure of casting of a dental alloy involves the conversion of a wax pattern of a restoration into a replicate. It is used in restorations such as onlays, inlays, crowns, bridges, and removable partial dentures. More or less all casting procedures are prepared by usage of alteration of lost-wax technique of casting process.[1],[2] Cast gold alloy is regarded as an ideal restorative material as it has advantages such as resistant to tarnish and corrosion, hardness, percentage elongation, castability, burnishability, and capacity to take high polish. Whereas, its extremely discernible color and high cost are its disadvantages.[1],[2],[3]

Recently, the usage of gold alloys is limited or eliminated due to its high cost. Base metal alloys satisfy properties of gold alloys with further advantages of reduced specific gravity and less cost. Hence, cobalt–chromium (Co–Cr) and nickel–Cr (Ni–Cr) alloys are enormously well liked in restorative dentistry procedures.[4],[5]

Composition of noble gold alloys allows it to be recasted over and over again without any loss of their required properties. However, recasting of base metal alloys has not been suggested owing to the paucity of research, with manufacturers instructing their single usage only.[5],[6],[7]

Metal wastes from laboratories are treated as health-care waste. They carry high potential for infection and injury. Hence, recycling or recasting alloys is an advantage, cost-wise and also environmentally.[8],[9]

We carried our study to gauge the characteristics of hardness, modulus of elasticity, and tensile strength of new alloy, and the same properties on different percentage permutations of new and once casted alloys.

 Materials And Methods



An in vitro study was carried on fifty specimens made from combining pure and once casted Ni–Cr alloy in different proportions, after obtaining institutional ethical committee clearance (number IEC/15/2016/MBDC). Sample size was determined from similar studies using the formula: n = [(zα + zβ) σd]2 Sample size of 50 was obtained with a confidence interval of 95% and power of 95% for the study. They were examined for hardness, tensile strength, and modulus of elasticity using microhardness tester [Figure 1] and [Figure 2] and universal testing machine (Instron 3365, U.K with 5 KN load cell and a rate of 5 mm/min) [Figure 3] and [Figure 4], respectively.{Figure 1}{Figure 2}{Figure 3}{Figure 4}

Fabrication of wax pattern of the tensile bar

A tensile bar was made in wax with a diameter of 2.4 mm and a gauge length of 15.4 mm, same as Moffa et al.[10] With a digital callipcaliperpatterns were standardized and were grouped into intogroups, each group of 10 samples were prepared the following manner.

Group I: To be cast using new alloy aloneGroup II: To be cast using 75% new alloy and 25% once casted alloyGroup III: To be cast using 50% of bothGroup IV: To be cast using 25% new alloy and 75% once casted alloyGroup V: To be cast using once casted alloy alone.

Sprue forming of the wax pattern

A preformed sprue wax wire (Renfert-Germany) of 3 mm diameter and 5 mm length was used for sprue forming. The patterns highest point was placed about 6 mm below the casting ring open end, so as to permit escape of gases throughout burnout stage and avert investment fracture owing to molten metal impact all through the casting process [Figure 5].{Figure 5}

Investing of wax pattern

Ringless technique was used for investing wax pattern. Investment of wax patterns was carried with carbon-free, phosphate-bonded investment material, Bellavest SH (Bego, Germany), immediately, based on the manufacturer's instructions. The material was mixed in a vacuum mixer (Renfert, Germany) for a time period of 90 s. A fine hair brush was used to paint the wax patterns with mixed investment. Then, casting rings were filled under mechanical vibration with investment material and allowed to bench set for 1 h.

Burnout of wax patterns

Specimens were kept in a burnout furnace (Sirodental, Italy) and the temperature of the furnace was gradually increased from room temperature to 5700°C with a holding time of 20 min and from 5700°C to 9800°C with a holding time of 20 min.

Casting

Casting was accomplished in an induction centrifugal casting machine (Fornax-T-Bego, Germany) with a base metal alloy (Girobond) with a composition of Ni 63.5%, Cr 24%, and Molybdenum 10%.

Divesting, finishing, and polishing of metal copings

Castings were divested, cleaned, and air abraded by sandblasting with 250 μ aluminum oxide powder at 0.6 MPa, (Cobra-Renfert) followed by steam cleaning using steam cleaner (Triton, Bego, Germany). Sprues were removed with carbide disks. The castings were observed under magnification and good illumination.

Measurement of microhardness

One end of the fractured bar was prepared for microhardness evaluation. Each specimen was embedded in acrylic resin. After polishing, Vickers hardness testing was accomplished using a 136° diamond in a microhardness tester (HMV-2 Microhardness tester, Shimadzu, Japan).

Statistical analysis

Results were plotted with a mean and standard deviation. The variance was analyzed using ANOVA. The difference between groups was detected by post hoc Tukey's test.

 Results



Comparison of tensile strength of five groups (ANOVA) demonstrated statistically insignificant difference between the Groups I, II, III, IV, and V [P = 0.081, i.e. P > 0.05, [Table 1]. For pairwise comparison of all groups, a post hoc Tukey test was done. There was insignificant variation among the groups [P > 0.05, [Table 2].{Table 1}{Table 2}

Comparison of modulus of elasticity of five groups (ANOVA) revealed statistically insignificant difference between the groups [P = 0.9789, i.e. P > 0.05, [Table 3]. Post hoc Tukey test showed insignificant difference between the groups [P > 0.05, [Table 4].{Table 3}{Table 4}

Hardness

ANOVA showed a statistically significant variation between all the groups [P < 0.001, [Table 5]. Post hoc Tukey test revealed insignificant variation among Groups I and II. However, when Group I was compared with Groups III, IV, and V, a significant difference was found [Table 6].{Table 5}{Table 6}

 Discussion



Casting is a complex procedure, with many stages, each affecting the dimensions and hence the accurateness of the final casting, which has to endure the rigors of the oral environment. The dimensional accuracy of the casting depends on the method employed and also on the various materials involved in its fabrication. Introduction of new materials and techniques so as to enhance the quality of these restorations warrants necessitating a constant monitoring of the entire process to ensure success.

The dental gold alloys contain all noble metals (except copper). Hence, sprues and buttons remaining after casting were used again for casting with addition of copper lost during the casting process. Presswood[11] reported a 0.01%–0.1% loss of component metals with each generation of the recast. According to him, recasting will not bring out any difference in alloy properties including hardness. He suggested that recasted alloy can be used at least once again.

According to Harcourt and Cotterill,[12] recasting may be carried out up to 13th generation without any loss of any physical properties of the alloy. He also suggested that entirely cleaned and deoxidized cast alloy need not be added with new alloy in any quantity. They evaluated the outcome of remelting of Co–Cr on their physical and chemical properties and found that remelting causes changes in the chemical composition of alloy that further results in reduction of fluidity and easiness of melting.

Nelson et al.[13] showed no notable degenerative changes in Ni–Cr alloy after recasting for ten generations. They also observed that combining used alloy with new alloy and recasting for 100 times revealed no significant changes in properties, microstructure, or clinical characteristics.

Hong et al.[14] confirmed that the repeated remelting of four generations of palladium-silver alloys introduced an alteration of the chemical composition and/or microstructure of the alloys. Sheffick[15] concluded that Co–Cr and Ni–Cr behaved inferiorly than the gold Type III alloys with inconsistent behavior in the compositions with remelting procedures. They stated that the first remelting of these alloys must be done by adding 50% by weight of new alloy, to enhance the castability and the percentage of constituents of these alloys.

Khamis and Seddik[16] observed Ni–Cr and Co–Cr commercial dental alloys on their corrosion behavior and stated that the corrosion resistance of alloy containing Co and molybdenum was not influenced by consecutive melting and recasting.

Mosleh et al.[17] revealed that the castability values for Ni–Cr alloy were insignificantly affected. Al-Hiyasat and Darmani[18] stated that reusage of base metal alloys at 50% and 100% significantly increased the cytotoxicity of the alloys studied (2 Ni–Cr, a Ni–Cr with Copper, a Copper–Cr, and a Copper–base). Furthermore, the amount of element released was seen to increase in ratio with the percentage of the recast alloys used.

Tensile strength

Hesby et al. demonstrated no major variations among the four generations of castings regarding hardness and tensile strength. Although tensile strength was affected insignificantly, it was found to be lesser than the minimum American with Disabilities Act (ADA) specification. They explained that the decreased tensile strength values are attributed to the difference in the sprue size and tensile bar which caused the bar to become prestressed during cooling.[19]

In this study, physical specifications for individual tensile strength were standardized, the dimensions of which were comparable to those suggested by Moffa et al.[10] The tensile strength values were greater than the calculated minimum specification for Ni–Cr alloys.

Modulus of elasticity

Nelson et al.[13] after recasting Ni–Cr alloy for ten generations found the mean modulus of elasticity values to be greater than the minimum ADA specification of 1.54 MPa × 106 MPa. In our study, the values of modulus of elasticity were 212–235 MPa.

Hardness

Hesby et al.[19] and Nelson et al.[13] did not find any significant difference in hardness values on recasting. Presswood[11] indicated that in each generation of recast, 0.01%–0.1% loss of components will be present. However, it does not contribute to any change in hardness. In our study, the values of hardness were greater than minimum specification for Ni–Cr alloys.

We suggest that it is prudent to use new alloy alone for casting. But considering economic and environmental factors, adding <50% reused alloy to new alloy is clinically acceptable.

Limitations

Exclusion of recasting effect on biocompatibility of Ni–Cr alloyEven though airborne contamination was minimized throughout the investigation by cautious concentration on detail in all phases of the technique, it might also have a say in difference observed between and within the groupsLack of application to in vivo conditions.

Future studies with a larger sample and more parameters might confirm the fact that adding of <50% reused alloy to pure alloy is satisfactory clinically, other benefits being cost effectiveness and environment-friendly.

 Conclusion



There was an insignificant difference in modulus of elasticity and tensile strength, and a significant variation in the hardness among the groups casted using various percentage combinations of Ni–Cr alloys.

Addition of reused alloy up to 50% was seen as clinically acceptable due to insignificant statistical variation among Groups I and II. However, significant statistical variation was noticed between Group III, IV, and V, indicating deterioration of properties when the content of reused alloy is 50% or more.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

References

1Jayaprakash K, Kumar Shetty KH, Shetty AN, Nandish BT. Effect of recasting on element release from base metal dental casting alloys in artificial saliva and saline solution. J Conserv Dent 2017;20:199-203.
2Sharma A, Rodrigues SJ, Shetty TB, Shenoy VK, Mundathaje M, Saldanha S, et al. Evaluation of effect of recasting of nickel-chromium alloy on its castability using different investment materials: An in vitro study. Indian J Dent Res 2016;27:190-4.
3Čairović A, Maksimović V, Radović K, Djurišić S. The effect of recasting on biological properties of Ni-Cr dental alloy. Srp Arh Celok Lek 2016;144:574-9.
4Tripuraneni SC, Namburi SK. Evaluation of genotoxicity of recycled Ni-Cr dental casting alloys: An in vitro study. J Appl Biomater Funct Mater 2018;6:47-54.
5Dr Gomathi G. A comparative analysis of the influence of new and recast alloy combinations on castability, chemical analysis, microstructural properties of Ni-Cr Alloy. IOSR J Dent Med Sci 2018;7:43-9.
6Wang H, Feng Q, Li N, Xu S. Evaluation of metal-ceramic bond characteristics of three dental Co-Cr alloys prepared with different fabrication techniques. J Prosthet Dent 2016;116:916-23.
7Meenakshi T, Bharathi M, Komala J. Evaluation of the effect of recasting nickel-chromium base metal alloy on the metal-ceramic bond strength: An in vitro study. J Contemp Dent Pract 2017;18:837-41.
8Thopegowda NB, Shenoy K, Shankaranarayana RK, Jayaprakash K, Gingipalli K, Vaddya SB, et al. Evaluation of mechanical properties of recasted dental base metal alloys for considering their reusability in dentistry and engineering field. Arch Med Health Sci 2014;2:178-83.
9Agrawal A, Hashmi SW, Rao Y, Garg A. Evaluation of surface roughness and tensile strength of base metal alloys used for crown and bridge on recasting (Recycling). J Clin Diagn Res 2015;9:ZC01-4.
10Moffa JP, Lugassy AA, Guckes AD, Gettleman L. An evaluation of nonprecious alloys for use with porcelain veneers. Part I. Physical properties. J Prosthet Dent 1973;30:424-31.
11Presswood RG. Multiple recast of a nickel-chromium-beryllium alloy. J Prosthet Dent 1983;50:198-9.
12Harcourt HJ, Cotterill WF. Induction melting of cobalt-chromium alloys; a comparison with flame melting. Br Dent J 1965;118:323-9.
13Nelson DR, Palik JF, Morris HF, Comella MC. Recasting a nickel-chromium alloy. J Prosthet Dent 1986;55:122-7.
14Hong JM, Razzoog ME, Lang BR. The effect of recasting on the oxidation layer of a palladium-silver porcelain alloy. J Prosthet Dent 1988;59:420-5.
15Sheffick LN. The effect of remelting and casting procedures on castability and chemical composition of dental alloys. MSc Thesis. College of Dentistry: University of Baghdad; 1993.
16Khamis E, Seddik M. Corrosion evaluation of recasting non-precious dental alloys. Int Dent J 1995;45:209-17.
17Mosleh I, Abdul-Gabbar F, Farghaly A. Castability evaluation and effect of recasting of ceramo-metal alloys. Egypt Dent J 1995;41:1357-62.
18Al-Hiyasat AS, Darmani H. The effects of recasting on the cytotoxicity of base metal alloys. J Prosthet Dent 2005;93:158-63.
19Hesby DA, Kobes P, Garver DG, Pelleu GB Jr. Physical properties of a repeatedly used nonprecious metal alloy. J Prosthet Dent 1980;44:291-3.